2U Rackmount ServerRS720-X7/RS8User Guide

Strona 2 - April 2012

xReferencesRefer to the following sources for additional information, and for product and software updates.1. ASUS Server Web-based Management (ASWM)

Strona 3 - Contents

5-30 Chapter 5: BIOS setup5.4.13 Serial Port Console Redirection COM1 Console Redirection [Disabled] Console Redirection Settings COM2 Conso

Strona 4

ASUS RS720-X7/RS8 5-31Data Bits [8]Conguration options: [7] [8]Parity [None]A parity bit can be sent with the data bits to detect some transmission e

Strona 5

5-32 Chapter 5: BIOS setupSerial Port for Out-of-Band Management/ Windows Emergency Management Services (EMS)Console Redirection [Disabled]Enables or

Strona 6

ASUS RS720-X7/RS8 5-335.4.14 OnboardLANCongurationLaunch INTEL W82574L OpROMOnboard LAN CongurationIntel LAN ROM Type [PXE]Intel LAN1 Enable

Strona 7 - REACH Information

5-34 Chapter 5: BIOS setup5.4.15 ME Subsystem Intel ME Subsystem Conguration ME BIOS Interface Version 1.2 ME Version 2.1.5.69 ME FW Status

Strona 8 - Safety information

ASUS RS720-X7/RS8 5-355.4.17 Runtime Error Logging Runtime Error Logging Support [Disabled]Runtime Error Logging Support [Disabled]This item allows

Strona 9 - About this guide

5-36 Chapter 5: BIOS setup5.5 Server Mgmt menuThe Server Mgmt menu displays the server management status, and allows you to change the settings.Aptio

Strona 10 - Typography

ASUS RS720-X7/RS8 5-375.5.1 System Event LogAptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Server Mgmt Change t

Strona 11 - Product introduction

5-38 Chapter 5: BIOS setup5.5.2 BMCnetworkcongurationAptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Server Mg

Strona 12 - 1.2 Serial number label

ASUS RS720-X7/RS8 5-395.6 Event Logs menuThe Event Logs allows you to change or view the event log settings.Aptio Setup Utility - Copyright (C) 2011

Strona 13 - 1.3 Systemspecications

1-This chapter describes the general features of the chassis kit. It includes sections on front panel and rear panel specications.Chapter 1Product i

Strona 14

5-40 Chapter 5: BIOS setupWhen Log is Full [Do Nothing]Allows you to choose the options for reactions to a full Smbios Event Log. Conguration options

Strona 15 - 1.4 Front panel features

ASUS RS720-X7/RS8 5-415.7 Boot menuThe Boot menu items allow you to change the system boot options.Number of seconds to wait for setup activation key

Strona 16 - 1.5 Rear panel features

5-42 Chapter 5: BIOS setupInterrupt 19 Capture [Enabled]Allows Option ROMs to trap interrupt 19. Conguration options: [Disabled] [Enabled] Boot Devic

Strona 17 - 1.6 Internal features

ASUS RS720-X7/RS8 5-435.8 Monitor menuThe Monitor menu displays the system temperature/power status, and allows you to change the fan settings.Scroll

Strona 18 - 1.7 LED information

5-44 Chapter 5: BIOS setupFAN Speed Control [Generic Mode]Allows you to congure the ASUS Smart Fan feature that smartly adjusts the fan speeds for mo

Strona 19 - 1.7.3 HDD status LED

ASUS RS720-X7/RS8 5-45User PasswordIf you have set a user password, you must enter the user password for accessing the system. To set a user password:

Strona 20

5-46 Chapter 5: BIOS setup5.11 Exit menuThe Exit menu items allow you to save or discard your changes to the BIOS items.Pressing <Esc> does not

Strona 21 - Hardware setup

ASUS RS720-X7/RS8 5-47Boot OverrideThese items displays the available devices. The device items that appears on the screen depends on the number of de

Strona 22 - 2.1 Chassis cover

5-48 Chapter 5: BIOS setup

Strona 23 - 2.2.1 Installing the CPU

This chapter provides instructions for setting up, creating and conguring RAID sets using the available utilities.Chapter 6RAIDconguration

Strona 24 - Chapter 2: Hardware setup2-4

Chapter 1: Product introduction1-2*ASUS System Web-based ManagementIf any of the above items is damaged or missing, contact your retailer.1.1 System

Strona 25 - 2-5ASUS RS720-X7/RS8

6-2 Chapter 6: RAID conguration6.1 Setting up RAIDThe motherboard comes with the Intel® C602-A controller that supports the following SATA RAID solu

Strona 26 - Chapter 2: Hardware setup2-6

ASUS RS720-X7/RS8 6-36.1.3 RAID controller selectionYou can choose either the LSI Software RAID Conguration Utility or the Intel Rapid Storage Techn

Strona 27

6-4 Chapter 6: RAID conguration3. The utility main window appears. Use the arrow keys to select an option from the Management Menu and then press &l

Strona 28 - Chapter 2: Hardware setup2-8

ASUS RS720-X7/RS8 6-56.2.1 Creating a RAID setThe LSI Software RAID Conguration Utility allows you to create a RAID 0, RAID 1, or RAID 10 set using

Strona 29 - 2.3 System memory

6-6 Chapter 6: RAID conguration3. Select all the drives required for the RAID set, and then press <F10> to congure array setting.4. Press &l

Strona 30

ASUS RS720-X7/RS8 6-75. Press <F10> again, the virtual drive information appears including a Virtual Drive menu that allows you to change the v

Strona 31 - 2.3.3 Installing a DIMM

6-8 Chapter 6: RAID conguration8. Select Units from the Virtual Drive sub-menu, and then press <Enter>.9. Select the units for virtual drive

Strona 32 - 2.4 Hard disk drives

ASUS RS720-X7/RS8 6-912. When nished setting the selected virtual drive conguration, select Accept from the menu, and then press <Enter>.Mana

Strona 33 - 2-13ASUS RS720-X7/RS8

6-10 Chapter 6: RAID congurationUsingNewCongurationWhen a RAID set already exists, using the NewConguration command erases the existing RAID con

Strona 34 - 2.5 Expansion slots

ASUS RS720-X7/RS8 6-116.2.2 AddingorviewingaRAIDcongurationYou can add a new RAID conguration or view an existing conguration using the View/

Strona 35

ASUS RS720-X7/RS8 1-31.3 SystemspecicationsThe ASUS RS720-X7/RS8 feature the ASUS Z9PR-D12/4L server board. The server supports Intel® LGA2011 Xeon

Strona 36

6-12 Chapter 6: RAID conguration6.2.3 Initializing the virtual drivesAfter creating the RAID set(s), you must initialize the virtual drives. You may

Strona 37 - 2.6 Cable connections

ASUS RS720-X7/RS8 6-133. Press <F10> to start initialization. When prompted, select Yes from the Initialize? dialog box, and then press <Ent

Strona 38 - RS720-E7/RS12

6-14 Chapter 6: RAID congurationUsingtheObjectscommandTo initialize the virtual drives using the Objects command1. From the Management Menu, sele

Strona 39 - 2.8.1 System fans

ASUS RS720-X7/RS8 6-153. Select Initialize from the pop-up menu, and then press <Enter> to start initialization.Management MenuCongure Initial

Strona 40

6-16 Chapter 6: RAID conguration6.2.4 Rebuilding failed drivesYou can manually rebuild failed hard disk drives using the Rebuild command in the Mana

Strona 41 - 2-21ASUS RS720-X7/RS8

ASUS RS720-X7/RS8 6-173. After selecting the drive to rebuild, press <F10>. When prompted, press <Y> to rebuild the drive.4. When rebuil

Strona 42 - 5. Set the SGPIO_SEL jumper

6-18 Chapter 6: RAID conguration6.2.5 Checking the drives for data consistencyYou can check and verify the accuracy of data redundancy in the select

Strona 43 - Installation options

ASUS RS720-X7/RS8 6-193. When prompted, use the arrow keys to select Yes from the Consistency Check? dialog box, and then press <Enter>. A pro

Strona 44 - Rail Washers

6-20 Chapter 6: RAID congurationUsingtheObjectscommandTo check data consistency using the Objects command1. From the Management Menu, select Obje

Strona 45 - 3-3ASUS RS720-X7/RS8

ASUS RS720-X7/RS8 6-216.2.6 DeletingaRAIDcongurationTo delete a RAID conguration1. From the Management Menu, select Congure > ClearCongur

Strona 46

Chapter 1: Product introduction1-4*Specicationsaresubjecttochangewithoutnotice.Model Name RS720-X7/RS8Networking LAN4 x Intel 82574L + 1 x Mgm

Strona 47 - 3-5ASUS RS720-X7/RS8

6-22 Chapter 6: RAID conguration6.2.7 Selecting the boot drive from a RAID setYou must have created a new RAID conguration before you can select th

Strona 48

ASUS RS720-X7/RS8 6-236.2.8 Enabling WriteCacheYou may manually enable the RAID controller’s WriteCache option after creating a RAID set to improve t

Strona 49 - Motherboard Info

6-24 Chapter 6: RAID conguration6.3 Intel® Rapid Storage Technology Option ROM UtilityThe Intel® Rapid Storage Technology Option ROM utility allows

Strona 50 - 4.1 Motherboard layout

ASUS RS720-X7/RS8 6-256.3.1 Creating a RAID setTo create a RAID set:1. From the utility main menu, select 1. Create RAID Volume and press <Enter&

Strona 51

6-26 Chapter 6: RAID conguration6. Use the up/down arrow keys to select the stripe size for the RAID array (for RAID 0, 10 and 5 only), and then pre

Strona 52 - 4.2 Jumpers

ASUS RS720-X7/RS8 6-272. Enter a name for the recovery set and press <Enter>.3. When the RAID Level item is selected, press the up/down arrow

Strona 53 - ASUS RS720-X7/RS8 4-5

6-28 Chapter 6: RAID conguration6.3.3 Deleting a RAID setTake caution when deleting a RAID set. You will lose all data on the hard disk drives when

Strona 54

ASUS RS720-X7/RS8 6-296.3.4 Resetting disks to Non-RAIDTake caution before you reset a RAID volume hard disk drive to non-RAID. Resetting a RAID volu

Strona 55 - ASUS RS720-X7/RS8 4-7

6-30 Chapter 6: RAID conguration6.3.5 Recovery Volume OptionsIf you have created a recovery set, you can congure more recovery set options followin

Strona 56 - 4.3 Internal connectors

ASUS RS720-X7/RS8 6-31Select a destination disk with the same size as the original hard disk.[ DEGRADED VOLUME DETECTED ][↑↓]-Previous/Next [ENTER]-S

Strona 57 - ASUS RS720-X7/RS8 4-9

ASUS RS720-X7/RS8 1-51.4 Front panel featuresThe barebone server displays a simple yet stylish front panel with easily accessible features. The power

Strona 58

6-32 Chapter 6: RAID conguration3. The utility immediately starts rebuilding after the disk is selected. The status of the degraded RAID volume is c

Strona 59 - ASUS RS720-X7/RS8 4-11

ASUS RS720-X7/RS8 6-336.3.8 Setting the Boot array in the BIOS Setup UtilityYou can set the boot priority sequence in the BIOS for your RAID arrays w

Strona 60

6-34 Chapter 6: RAID conguration

Strona 61 - ASUS RS720-X7/RS8 4-13

This chapter provides instructions for installing the necessary drivers for different system components.Chapter 7Driver installation

Strona 62

7-2 Chapter 7: Driver installation7.1 RAID driver installationAfter creating the RAID sets for your server system, you are now ready to install an op

Strona 63 - 12. EATX power connectors

ASUS RS720-X7/RS8 7-36. Locate the RAID driver and place a blank, high-density oppy disk to the oppy disk drive.7. Press <Enter>.8. Follow

Strona 64

7-4 Chapter 7: Driver installationTo create a RAID driver disk in Windows® environment1. Start Windows®.2. Place the motherboard support DVD into

Strona 65 - ASUS RS720-X7/RS8 4-17

ASUS RS720-X7/RS8 7-57.1.2 Installing the RAID controller driverDuring Windows® Server 2008 OS installationTo install the RAID controller driver when

Strona 66

7-6 Chapter 7: Driver installation4. A message appears, reminding you to insert the installation media containing the driver of the RAID controller d

Strona 67 - 4.4 Internal LEDs

ASUS RS720-X7/RS8 7-73. Select Yes using the <Tab> key when asked if you have the driver disk, then press <Enter>.Main MenuDo you have a

Strona 68 - 4. Location LED (LOCLED2)

Chapter 1: Product introduction1-6• The ports for the PS/2 keyboard, PS/2 mouse, USB, VGA, and Gigabit LAN do not appear on the rear panel if mother

Strona 69 - ASUS RS720-X7/RS8 4-21

7-8 Chapter 7: Driver installation5. When asked if you will load additional RAID controller drivers, select No, then press <Enter>.More Driver

Strona 70

ASUS RS720-X7/RS8 7-9Red Hat® Enterprise Linux OS 6.1To install the LSI MegaRAID controller driver when installing Red Hat® Enterprise OS:1. Boot the

Strona 71 - BIOS setup

7-10 Chapter 7: Driver installation4. Select Yes using the <Tab> key when asked if you have the driver disk, then press <Enter>.Main Menu

Strona 72

ASUS RS720-X7/RS8 7-116. Insert the Red Hat® Enterprise RAID driver disk to the USB oppy disk drive, select OK, then press <Enter>. The drive

Strona 73 - Drive Folder Info

7-12 Chapter 7: Driver installationPreparing the Linux DriverEnsure that there is another computer with a Linux-based OS to create the RAID driver. Wh

Strona 74 - 5.1.3 BUPDATER utility

ASUS RS720-X7/RS8 7-13SUSE Linux 11 OSTo install the LSI MegaRAID controller driver when installing SUSE Linux Enterprise Server OS:1. Boot the syste

Strona 75 - ASUS RS720-X7/RS8 5-5

7-14 Chapter 7: Driver installation4. Use the USB drive to provide the third-party driver during the OS installation. Type the command brokenmodules=

Strona 76 - 5.2 BIOS setup program

ASUS RS720-X7/RS8 7-157.2 Intel® chipset device software installationThis section provides the instructions on how to install the Intel® chipset dev

Strona 77 - 5.2.1 BIOS menu screen

7-16 Chapter 7: Driver installation5. Select Yes to accept the terms of the License Agreement and continue the process.6. Read the Readme File Infor

Strona 78 - 5-8 Chapter 5: BIOS setup

ASUS RS720-X7/RS8 7-178. Select Yes, I want to restart my computer now and click Finish to restart your computer before using the program.

Strona 79 - 5.3 Main menu

ASUS RS720-X7/RS8 1-71.6 Internal featuresThe barebone server includes the basic components as shown.The barebone server does not include a oppy dis

Strona 80 - 5.4 Advanced menu

7-18 Chapter 7: Driver installation7.3 Intel@ Network Connections Software installationThis section provides the instructions on how to install the

Strona 81 - ASUS RS720-X7/RS8 5-11

ASUS RS720-X7/RS8 7-195. Click Next when the Intel(R) Network Connections–InstallShield Wizard window appears. 7. Click the Intel(R) PROSet for Wind

Strona 82 - 5-12 Chapter 5: BIOS setup

7-20 Chapter 7: Driver installation8. Follow the screen instructions to complete installation.9. When nished, press Finish to continue.

Strona 83 - ASUS RS720-X7/RS8 5-13

ASUS RS720-X7/RS8 7-217.4 VGA driver installationThis section provides the instructions on how to install the ASPEED Video Graphics Adapter (VGA) dri

Strona 84 - 5.4.3 ChipsetConguration

7-22 Chapter 7: Driver installation5. Toggle I accept the terms in the license agreement and click Next to continue.6. Enter the user information an

Strona 85 - ASUS RS720-X7/RS8 5-15

ASUS RS720-X7/RS8 7-239. When the installation completes, click Finish to restart your computer before using the program.8. Click Install to start d

Strona 86 - 5-16 Chapter 5: BIOS setup

7-24 Chapter 7: Driver installation7.5 Intel® C600 Series Chipset SCU SATA RAID DriversThis section provides the instructions on how to install the

Strona 87 - DIMM Information

ASUS RS720-X7/RS8 7-257.6 Intel® Rapid Storage Technology enterprise 3.0 installationThis section provides the instructions on how to install the In

Strona 88 - SCU devices [Enabled]

7-26 Chapter 7: Driver installation5. Read the Warning message and click Next to continue.6. Read the License Agreement and click Yes to continue.7.

Strona 89 - Auto Conguration

ASUS RS720-X7/RS8 7-279. Select Yes, I want to restart my computer now and click Finish to restart your computer before using the program.8. After c

Strona 90 - 5.4.4 PCHSATAConguration

Chapter 1: Product introduction1-81.7 LED information1.7.1 Front panel LEDs1.7.2 LAN (RJ-45) LEDsACT/LINK LED SPEED LEDStatus Description Status D

Strona 91 - 5.4.5 PCHSCUConguration

7-28 Chapter 7: Driver installation7.7 Intel® WG82574L Gigabit Adapters Driver installationThis section provides the instructions on how to install

Strona 92 - 5.4.6 PCI Subsystem Settings

ASUS RS720-X7/RS8 7-294. When the Intel® PRO Network Connections – InstallShield Wizard window appears, click Next to start the installation. 5. Sel

Strona 93 - ASPM Support [Disabled]

7-30 Chapter 7: Driver installation6. Select the programs you want to install and click Next to continue. 7. Click Install to start the installation

Strona 94 - 5-24 Chapter 5: BIOS setup

ASUS RS720-X7/RS8 7-318. The programs you select are being installed.9. Click Finish to nish the installation. 10. Restart your computer before us

Strona 95 - TXT(LT) Hardware Support

7-32 Chapter 7: Driver installation7.8 Management applications and utilities installationThe support DVD that came with the motherboard package con

Strona 96 - 5.4.8 USBConguration

ASUS RS720-X7/RS8 7-337.8.3 Utilities menuThe Utilities menu displays the software applications and utilities that the motherboard supports. Click an

Strona 97 - 5.4.9 Trusted Computing

7-34 Chapter 7: Driver installation

Strona 98 - 5.4.11 WHEAConguration

ASUS RS700-X7/PS4 A-1ASUS contact informationASUSTeK COMPUTER INC.Address 15 Li-Te Road, Peitou, Taipei, Taiwan 11259Telephone +886-2-2894-3447

Strona 99 - 5.4.12 APM setting

ASUS contact informationASUS COMPUTER INTERNATIONAL (America)Address 800 Corporate Way, Fremont, CA 94539, USAFax +1-510-608-4555Web site h

Strona 100 - Console Redirection Settings

ASUS RS720-X7/RS8 1-91.7.3 HDD status LEDSATAII/SAS HDD LED DescriptionHDD Status LEDGREEN ON SATAII/SAS HDD power ONRED ONHDD has failed and should

Strona 101 - Console Redirection [Enabled]

iiCopyright © 2012 ASUSTeK COMPUTER INC. All Rights Reserved.No part of this manual, including the products and software described in it, may be repro

Strona 102 - Management Services (EMS)

Chapter 1: Product introduction1-10

Strona 103 - ASUS RS720-X7/RS8 5-33

2-This chapter lists the hardware setup procedures that you have to perform when installing or removing system components.Chapter 2Hardware setup

Strona 104 - 5.4.15 ME Subsystem

Chapter 2: Hardware setup2-22.1 Chassis cover1. Loosen the two thumbscrews on the rear panel to release the rear cover from the chassis.Removing th

Strona 105 - Advanced

2-3ASUS RS720-X7/RS82.2 Central Processing Unit (CPU)The motherboard comes with two surface mount LGA 2011 Socket R designed for the Intel® Xeon® E5-

Strona 106 - 5.5 Server Mgmt menu

Chapter 2: Hardware setup2-42. Press the left load lever with your thumb (A), then move it to the left (B) until it is released from the retention t

Strona 107 - 5.5.1 System Event Log

2-5ASUS RS720-X7/RS8IH7. Remove the PnP cap (H) from the CPU socket and close the load plate (I).GF5. Push the left load lever (F) to lift the load

Strona 108 - Gateway IP address [0.0.0.0]

Chapter 2: Hardware setup2-6KJ8. Push down the right load lever (J), ensuring that the edge of the load plate is xed by the lever (K).9. Insert th

Strona 109 - 5.6 Event Logs menu

2-7ASUS RS720-X7/RS8The Thermal Interface Material is toxic and inedible. DO NOT eat it. If it gets into your eyes or touches your skin, wash it off i

Strona 110 - View System Event Log

Chapter 2: Hardware setup2-82. Twist each of the four screws with a Philips (cross) screwdriver just enough to attach the heatsink to the motherboar

Strona 111 - 5.7 Boot menu

2-9ASUS RS720-X7/RS82.3 System memory2.3.1 OverviewThe motherboard comes with eight (for CPU1) and four (for CPU2) Double Data Rate 3 (DDR3) Dual In

Strona 112 - Boot Option Priorities

iiiContentsNotices ... viiSafety information ...

Strona 113 - 5.8 Monitor menu

Chapter 2: Hardware setup2-102CPUCongurationA1 A2 B1 B2 C1 C2 D1 D2 E1 F1 G1 H11 DIMMs•2 DIMMs• •3 DIMMs• • •4 DIMMs• • • •5 DIMMs• • • • •6 DIMM

Strona 114 - 5.9 Security menu

2-11ASUS RS720-X7/RS82.3.3 Installing a DIMM3. Hold the DIMM by both of its ends, then insert the DIMM vertically into the socket. Apply force to bo

Strona 115 - ASUS EZ Flash 2 Utility

Chapter 2: Hardware setup2-122.4 Hard disk drivesThe hard disk drive installed on the drive tray connects to the motherboard SATA/SAS ports via the

Strona 116 - 5.11 Exit menu

2-13ASUS RS720-X7/RS85. Carefully insert the drive tray and push it all the way to the depth of the bay until just a small fraction of the tray edge

Strona 117 - Boot Override

Chapter 2: Hardware setup2-142.5 Expansion slotsIn the future, you may need to install expansion cards. The following subsections describe the slots

Strona 118 - 5-48 Chapter 5: BIOS setup

2-15ASUS RS720-X7/RS82.5.2 ConguringanexpansioncardAfter installing the expansion card, congure the it by adjusting the software settings.1. Tu

Strona 119 - RAIDconguration

Chapter 2: Hardware setup2-162.5.3 PCI Express x16 slot (x16 link)The onboard PCIE 2 slot provides one x16 Gen3 link to CPU1 and auto switches to x8

Strona 120 - 6.1 Setting up RAID

2-17ASUS RS720-X7/RS82.6 Cable connections• The bundled system cables are pre-connected before shipment. You do not need to disconnect t

Strona 121 - ASUS RS720-X7/RS8 6-3

Chapter 2: Hardware setup2-182.7 SATA/SAS backplane cablingRS720-E7/RS12Connects a 8-pin plug from power supplyOnboard SGPIO1: Connects to the SGPIO

Strona 122

2-19ASUS RS720-X7/RS82.8 Removable/optional componentsYou may need to remove previously installed system components when installing or removing syste

Strona 123 - 6.2.1 Creating a RAID set

ivContentsChapter 3: Installation options3.1 Installing friction rail kit items ... 3-23.1.1 Attac

Strona 124

Chapter 2: Hardware setup2-202.8.2 Redundant power supply moduleTo install a second redundant power supply module:1. Remove the redundant power sup

Strona 125 - ASUS RS720-X7/RS8 6-7

2-21ASUS RS720-X7/RS82.8.3 Installing ASUS PIKE RAID card (optional)Follow the steps below to install an optional ASUS RAID card on your motherboard.

Strona 126 - Select Units For VD Size

Chapter 2: Hardware setup2-225. Set the SGPIO_SEL jumper on the backplane to pin2-3 when connecting data cables to the PSAS connectors on the mother

Strona 127 - ASUS RS720-X7/RS8 6-9

2-This chapter describes how to install the optional components and devices into the barebone server.Chapter 3Installation options

Strona 128 - UsingNewConguration

Chapter 3: Installation options3-2Fixing latch3.1.1 AttachingthexinglatchestotheserverRefer to the gures below for the locations to attach t

Strona 129 - ASUS RS720-X7/RS8 6-11

3-3ASUS RS720-X7/RS81. Select a 1U space on the rack where you want to install the rack rail. A 1U space consists of three square mounting holes with

Strona 130 - Using the Initialize command

Chapter 3: Installation options3-4Do not install the rail kit in the following situation:DO NOT place the rail hook on a thick lip of the mounting ho

Strona 131 - ASUS RS720-X7/RS8 6-13

3-5ASUS RS720-X7/RS83.1.2 Mounting the server to the rackTo mount the server to the rack1. Align the server rails with the rack rails, then push the

Strona 132 - UsingtheObjectscommand

Chapter 3: Installation options3-6

Strona 133 - ASUS RS720-X7/RS8 6-15

This chapter includes the motherboard layout and brief descriptions of the jumpers and internal connectors.Chapter 4Motherboard Info

Strona 134 - Rebuild PD(s)

vContents5.4.7 Intel TXT(LT-SX) Conguration ... 5-255.4.8 USB Conguration ...

Strona 135 - ASUS RS720-X7/RS8 6-17

Chapter 4: Motherboard information4-24.1 Motherboard layoutLayout contentsJumpers Page1. Clear RTC RAM (CLRTC1) 4-42. VGA controller setting (3-pin

Strona 136 - Check Consistency

ASUS RS720-X7/RS8 4-3Internal connectors Page1. Serial ATA connectors (SATA 6Gb/s: 7-pin SATA1, SATA2 [Blue]) (SATA 3Gb/s: 7-pin SATA3, SATA4, SA

Strona 137 - ASUS RS720-X7/RS8 6-19

Chapter 4: Motherboard information4-44.2 Jumpers1. Clear RTC RAM (CLRTC1)This jumper allows you to clear the Real Time Clock (RTC) RAM in CMOS. You

Strona 138

ASUS RS720-X7/RS8 4-52. VGA controller setting (3-pin VGA_EN1)This jumper allows you to enable or disable the onboard VGA controller. Set to pins 1–2

Strona 139 - ASUS RS720-X7/RS8 6-21

Chapter 4: Motherboard information4-64. LSIMegaRAIDorIntelRSTeselectionjumper(3-pinRAID_SEL1)This jumper allows you to select the PCH SATA RA

Strona 140 - BIOS Version A.10.09231523R

ASUS RS720-X7/RS8 4-76. DDR3 thermal event setting (3-pin DIMMTRIP1)This jumper allows you to enable/disable DDR3 DIMM thermal sensing event pin.7.

Strona 141 - 6.2.8 Enabling WriteCache

Chapter 4: Motherboard information4-84.3 Internal connectors1. Serial ATA connectors (SATA 6Gb/s: 7-pin SATA1, SATA2 [Blue]) (SATA 3Gb/s: 7-pin SATA

Strona 142 - Option ROM Utility

ASUS RS720-X7/RS8 4-92. SATA connectors — ISAS connectors (7-pin ISAS1–4 [Gray]) Supported by the Intel® C602-A PCH, ISAS 1-4 connectors connect to

Strona 143 - 6.3.1 Creating a RAID set

Chapter 4: Motherboard information4-104. Hard disk activity LED connector (4-pin HDLED1)This LED connector is for the storage add-on card cable conne

Strona 144

ASUS RS720-X7/RS8 4-117. CPU, front and rear fan connectors (4-pin CPU_FAN1-2, FRNT_FAN1–4, REAR_FAN1-2)The fan connectors support cooling fans. Conn

Strona 145 - ASUS RS720-X7/RS8 6-27

viContents6.2.7 Selecting the boot drive from a RAID set ... 6-226.2.8 Enabling WriteCache ...

Strona 146 - 6.3.3 Deleting a RAID set

Chapter 4: Motherboard information4-128. LAN LED connector (LAN34_LED1) This LED connector supports LAN3 and LAN4 LEDs.The LAN LEDs function on

Strona 147 - ASUS RS720-X7/RS8 6-29

ASUS RS720-X7/RS8 4-139. Serial General Purpose Input/Output connectors (8-1 pin PSGPIO1/2, ISGPIO1, SGPIO1)The SGPIO 1 connectors are used for

Strona 148 - 6.3.2 Creating a Recovery set

Chapter 4: Motherboard information4-1410. Serial port connectors (10-1 pin COM1/COM2)These connectors are for the serial (COM) ports. Connect the ser

Strona 149 - 6.3.6 Exiting the Intel

ASUS RS720-X7/RS8 4-1512. EATX power connectors (24-pin EATXPWR1, 8-pin EATX12V1/EATX12V2)These connectors are for the EATX power supply plugs. The

Strona 150

Chapter 4: Motherboard information4-1613. Power Supply SMBus connector (5-pin PSUSMB1)This connector allows you to connect SMBus (System Management B

Strona 151 - ASUS RS720-X7/RS8 6-33

ASUS RS720-X7/RS8 4-1714. System panel connector (20-1 pin PANEL1)This connector supports several chassis-mounted functions.1) System power LED (3-p

Strona 152

Chapter 4: Motherboard information4-1815. Auxiliary panel connector (20-2 pin AUX_PANEL1)This connector is for additional front panel features includ

Strona 153 - Driver installation

ASUS RS720-X7/RS8 4-194.4 Internal LEDs1. Standby Power LED The motherboard comes with a standby power LED. The green LED lights up to indicate tha

Strona 154 - 7.1 RAID driver installation

Chapter 4: Motherboard information4-203. CATT Error LED (CATTERR_LED1) Indicates that the system has experienced a fatal or catastrophic error and

Strona 155 - LSI 2008 SAS2 Driver

ASUS RS720-X7/RS8 4-215. CPU warning LED (ERR_CPU1/2) The CPU warning LEDs light up to indicate an impending failure of the corresponding CPU.

Strona 156

viiNoticesFederal Communications Commission StatementThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two con

Strona 157 - Server 2008 OS installation

Chapter 4: Motherboard information4-22

Strona 158

This chapter tells how to change the system settings through the BIOS Setup menus. Detailed descriptions of the BIOS parameters are also provided.Chap

Strona 159 - Enterprise Linux OS 5.6

5-2 Chapter 5: BIOS setup5.1 Managing and updating your BIOSThe following utilities allow you to manage and update the motherboard Basic Input/Output

Strona 160 - Do you wish to load any more

ASUS RS720-X7/RS8 5-33. Press <Tab> to switch to the Drive eld.4. Press the Up/Down arrow keys to nd the USB ash disk that contains the lat

Strona 161 - Enterprise Linux OS 6.1

5-4 Chapter 5: BIOS setup5.1.3 BUPDATER utilityThe succeeding BIOS screens are for reference only. The actual BIOS screen displays may not be the sam

Strona 162

ASUS RS720-X7/RS8 5-54. The utility veries the le, then starts updating the BIOS le.DO NOT shut down or reset the system while updating the BIOS t

Strona 163 - ASUS RS720-X7/RS8 7-11

5-6 Chapter 5: BIOS setup5.2 BIOS setup programThis motherboard supports a programmable rmware chip that you can update using the provided utility d

Strona 164 - Preparing the Linux Driver

ASUS RS720-X7/RS8 5-75.2.2 Menu barThe menu bar on top of the screen has the following main items:Main For changing the basic system conguration

Strona 165 - SUSE Linux 11 OS

5-8 Chapter 5: BIOS setup5.2.3 Menu itemsThe highlighted item on the menu bar displays the specic items for that menu. For example, selecting Main s

Strona 166 - Other device

ASUS RS720-X7/RS8 5-95.3 Main menuWhen you enter the BIOS Setup program, the Main menu screen appears. The Main menu provides you an overview of the

Strona 167 - chipset device software

viiiSafety informationElectrical Safety• Before installing or removing signal cables, ensure that the power cables for the system unit and all attach

Strona 168

5-10 Chapter 5: BIOS setup5.4 Advanced menuThe Advanced menu items allow you to change the settings for the CPU and other system devices.Be cautious

Strona 169 - ASUS RS720-X7/RS8 7-17

ASUS RS720-X7/RS8 5-11Socket 1 CPU InformationEnter to view socket CPU Information.Socket 1 CPU InformationGenuine Intel(R) CPU @ 2.60GHzCPU Signature

Strona 170 - 7.3 Intel

5-12 Chapter 5: BIOS setupAdjacentCacheLinePrefetch[Enabled]This Item allows you to turn on/off prefetching of adjacent cache lines. Conguration

Strona 171 - ASUS RS720-X7/RS8 7-19

ASUS RS720-X7/RS8 5-13Turbo Mode [Enabled]Conguration options: [Disabled] [Enabled] P-STATE Coordination [HW_ALL]This item allows you to change P-STA

Strona 172

5-14 Chapter 5: BIOS setup QPI Conguration Memory Conguration CPU II0 Bridge Conguration PCH Conguration Intel(R) VT for Directed I/O Conguration

Strona 173 - 7.4 VGA driver installation

ASUS RS720-X7/RS8 5-15MemoryCongurationSupport for compatibility Revision ID(CRID) Functionality mentioned in Sandybridge bios spec.Compatibility RI

Strona 174

5-16 Chapter 5: BIOS setupPatrol Scrub [Disabled]Allows you to enable/disable Patrol Scrub. Conguration options: [Disabled] [Enabled]Demand Scrub [En

Strona 175 - 8. Click

ASUS RS720-X7/RS8 5-17Enables/Disables Intel(R) I/O Acceleration Technology (I/OAT).Intel(R) I/OAT [Disabled]DCA Support [Enabled]

Strona 176 - RAID Drivers

5-18 Chapter 5: BIOS setupPCHCongurationSupport for PCH Compatibility Revision ID(CRID) functionality.→←: Select Screen ↑↓: Select Item Enter: Sele

Strona 177 - 7.6 Intel

ASUS RS720-X7/RS8 5-19Enables or Disables BIOS ACPI Auto Conguration.Intel(R) VT-d [Disabled]Intel(R) VT-d [Disabled]Allows you to enable or di

Strona 178

ixAbout this guideAudienceThis user guide is intended for system integrators, and experienced users with at least basic knowledge of conguring a serv

Strona 179 - ASUS RS720-X7/RS8 7-27

5-20 Chapter 5: BIOS setup5.4.4 PCHSATAConguration(1)IDE Mode. (2)AHCI Mode. (3)RAID Mode.→←: Select Screen ↑↓: Select Item Enter: Select Item +/

Strona 180 - WG82574L Gigabit Adapters

ASUS RS720-X7/RS8 5-215.4.5 PCHSCUCongurationThis menu automatically detects and displays Device 1-4. Device1 Not Present Device2 Not Present

Strona 181 - 4. When the Intel

5-22 Chapter 5: BIOS setup5.4.6 PCI Subsystem SettingsIn case of multiple Option ROMs (Legacy and EFI Compatible), species what PCI option ROM to la

Strona 182

ASUS RS720-X7/RS8 5-23PCI Express SettingsEnables or DisablesPCI Express Device Relaxed Ordering.PCI Express Link Register SettingsASPM Support [D

Strona 183 - ASUS RS720-X7/RS8 7-31

5-24 Chapter 5: BIOS setupPCIESlotOptionRomCongurationEnables or disables boot option for legacy mass storage device with option ROM.Legacy 0p

Strona 184 - installation

ASUS RS720-X7/RS8 5-25This is the Intel Trusted Execution Technology (TXT) feature. VT and VT-d support must be enabled before using this feature..Ins

Strona 185 - 7.8.3 Utilities menu

5-26 Chapter 5: BIOS setup5.4.8 USBCongurationEnabled Legacy USB support. AUTO option disables legacy support if no USB devices are connected. DISA

Strona 186

ASUS RS720-X7/RS8 5-27Enable/Disable (EHCI) Support.EHCI Controller 1 [Enabled]EHCI Controller 2 [Enabled]Rear USB #1 [Enabled]Rear U

Strona 187 - ASUS contact information

5-28 Chapter 5: BIOS setup5.4.10 ACPI SettingsEnables or Disables BIOS ACPI Auto Conguration.ACPI SettingsEnable ACPI Auto Conguration [Disabled]

Strona 188

ASUS RS720-X7/RS8 5-295.4.12 APM settingSpecify what state to go to when power is re-applied after a power failure (G3 state).Restore AC Power Loss

Komentarze do niniejszej Instrukcji

Brak uwag