A-12 Using the CFGGEN IR Configuration Utility
Version 1.1 Copyright © 2006, 2007 by LSI Logic Corporation. All rights reserved.
2. CFGGEN does not allow adding a hot spare disk of a type
(SAS/SATA) that is different from the disk types in any of the
volumes.
Command Line
cfggen <controller #> hotspare <SCSI ID>
cfggen <controller #> hotspare bay <enclosure:bay>
Parameters
<controller #> Number of the SAS controller targeted by this
command.
Bay This option indicates that enclosure:bay values are specified
instead of SCSI ID values.
<SCSI ID> SCSI ID of the drive targeted by this command.
<enclosure:bay> – The enclosure:bay value for the disk drive to use
for the new hot spare disk. These values can be obtained via the
output of the DISPLAY command.
Program Return Value
0x00 SUCCESS: command completed successfully.
0x01 FAILURE: bad command line arguments or operational failure.
A.3.7 STATUS Command
The STATUS command displays the status of any volume
synchronization operation that is currently in progress on the controller.
If no such operation is in progress, CFGGEN displays a message
indicating this before it exits. The STATUS command adds the flag
Inactive to the Volume State field, if the controller firmware marks the
volume as Inactive.
Command Line
cfggen <controller #> status
Parameters
<controller #> Number of the SAS controller targeted by this
command.
Przeglądanie stron 59