Przeglądanie stron 61
A-14 Using the CFGGEN IR Configuration Utility
Version 1.1 Copyright © 2006, 2007 by LSI Logic Corporation. All rights reserved.
the disk is still associated with the volume and therefore cannot be
addressed by normal I/O requests. If a new disk replaces an offline disk,
the new disk is automatically brought online. Otherwise, the disk remains
offline until explicitly brought online by SETONLINE command.
Command Line
cfggen <controller #> setoffline <SCSI ID>
Parameters
<controller #> Number of the SAS controller targeted by this
command.
<SCSI ID> SCSI target ID of the drive targeted by this command.
Program Return Value
0x00 SUCCESS: command completed successfully.
0x01 FAILURE: command failed.
A.3.9 SETONLINE Command
Note: The SETONLINE command is supported by the DOS,
Linux, and WinPE versions of CFGGEN only.
The SETONLINE command brings a physical disk in a volume online.
This is required only after the physical disk has been taken offline by the
SETOFFLINE command. When a physical disk is brought online, the IOC
synchronizes the volume.
Command Line
cfggen <controller #> setonline <SCSI ID>
Parameters
<controller #> Number of the controller targeted by this
command.
<SCSI ID> SCSI target ID of the drive targeted by this command.