Test Report ------------------------------------------------------------------------------ 13/47
Report No.: A5415648, FCC Part 15
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
1.7 Test Procedure
All measurements contained in this report were performed mainly according to the techniques
described in ANSI C63.4 (1992) and the pre-setup was written on 1.3 test method, the detail setup
was written on each test item.
1.8 Location of the Test Site
The radiated emissions measurements required by the rules were performed on the
three-meter, Anechoic Chamber (Registration Number: 93906) maintained by Training
Research Co., Ltd. 1F, No. 255 Nanyang Street, Shijr, Taipei Hsien 221, Taiwan, R.O.C. Complete
description and measurement data have been placed on file with the commission. The conducted
power line emissions tests and other test items were performed in a anechoic chamber also located at
Training Research Co., Ltd.
No. 255 Nanyang Street, Shijr, Taipei Hsien 221, Taiwan, R.O.C. Training Research Co.,
Ltd. is listed by the FCC as a facility available to do measurement work for others on a contract
basis.
1.9 General Test Condition
The conditions under which the EUT operates were varied to determine their effect on the
equipment's emission characteristics. The final configuration of the test system and the mode of
operation used during these tests were chosen as that which produced the highest emission levels.
However, only those conditions, which the EUT was considered likely to encounter in normal use
were investigated.
In test, they were set in high power and continuously transmitting mode that controlled by
computer. The ch01, ch06 and ch11 of EUT were all tested. The setting up procedure is recorded on
1.3 test method.