Test Report ------------------------------------------------------------------------------ 16/47
Report No.: A5415648, FCC Part 15
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
IV. Section 15.207: Power Line Conducted Emissions for AC Powered Units
4.1 Test Condition & Setup
The power line conducted emission measurements were performed in an anechoic chamber.
The EUT was assembled on a wooden table, which is 80 centimeters high, was placed 40 centimeters
from the backwall and at least 1 meter from the sidewall.
Power was fed to the EUT from the public utility power grid through a line filter and Line
Impedance Stabilization Networks (LISNs). The LISN housing, measuring instrumentation case,
ground plane, etc., were electrically bonded together at the same RF potential. The Spectrum
analyzer (or EMI receiver) was connected to the AC line through an isolation transformer. The
50-ohm output of the LISN was connected to the spectrum analyzer directly. Conducted emission
levels were in the CISPER quasi-peak and average detection mode. The analyzer's 6 dB bandwidth
was set to 9 KHz. No post-detector video filter was used.
The spectrum was scanned from 150 KHz to 30 MHz. The physical arrangement of the test
system and associated cabling was varied (within the scope of arrangements likely to be encountered
in actual use) to determine the effect on the unit's emanations in amplitude and frequency. All
spurious emission frequencies were observed. The highest emission amplitudes relative to the
appropriate limit were measured and have been recorded in paragraph 2.4.
There is a test condition apply in this test item, the test procedure description as <1.3>. Three
channels were tested, one in the top (CH01), one in the middle (CH06) and the other in bottom
(CH11).
4.2 List of Test Instruments
Calibration Date
Instrument Name Model No. Brand Serial No. Last time Next time
EMI Receiver 8546A H P 3520A00242 06/28/02 06/28/03
RF Filter Section 85460A H P 3448A00217 06/28/02 06/28/03
LISN (EUT) LISN-01 TRC 9912-03,04 06/04/02 06/04/03
LISN (Support E.) LISN-01 TRC 9912-05 07/15/02 07/15/03
Auto Switch Box ASB-01 TRC 9904-01 11/20/02 11/20/03
(< 30MHz)
The level of confidence of 95%, the uncertainty of measurement of conducted emission is ± 2.02 dB.