Lock PropertiesAD-Series Locks and Controllers
AD-200/250 (Oine Locks)
EDIT Tab
Property Description Default
Lock Type Classroom: Unlocks when a credential is presented and then automatically locks
aer the relock delay has expired.
Oce: Unlocks when a credential is presented and then automatically locks aer the
relock delay has expired. To keep the door unlocked, push the button on the inside.
The button will momentarily illuminate green. To return the lock to the locked state,
push the button again or present a credential to the outside.
Privacy: To initiate the Privacy function, with the door closed, push the button on the
inside of the door. This prevents normal credentials from opening the door from the
outside.
The lock will go back to its normal state when the button is pushed again or when the
door position switch indicates that the door has opened.
When using a Mortise Deadbolt, extending the deadbolt from the inside lights a
red LED on the inside trim and initiates the Privacy function which prevents normal
credentials from opening the door from the outside. The lock can always be opened
using a Pass-Through credential or mechanical key in case of emergency.
Apartment: The apartment function lock is normally locked and never relocks
automatically, which prevents users from being locked out.
To unlock the door from the outside, present a credential.
To unlock the door from the inside, push the inside button or, if using the MD chassis,
retract the deadbolt. Egress always available from inside.
When lever is rotated and door is opened, the request-to-exit switch is used in
conjunction with the door position switch to cause the door to return to unlocked
condition.
To lock the door from the outside, present a credential.
To lock the door from the inside, push the inside button or, for MD chassis, extend the
deadbolt.
Set by the
Factory
PIN Length
(AD-200 only)
Maximum number of digits in the user PIN. Range of 3 to 6 digits. 6
Allow Privacy Mode
Override
(AD-250 only)
When enabled, allows cards to override a lock that has been placed in privacy mode.
When disabled, only cards specifically assigned to this door will have access.
Disabled
Ignore Keypad If checked, key entry codes are ignored. Disabled
Record Lock/Unlock If checked and supported by the system soware, will record an audit event when the
Inside Push button is pressed.
Disabled
Enable/Disable
Interior LED Status
Blinking
Enables or Disables the interior LED’s status blinking.
When enabled: (enables two options to be checked)
Blink Interior Button LED when locked - Blinks the Interior LED Red every 30
seconds.
Blink Interior LED Rapidly when in Privacy Mode - Interior LED will flash rapidly
while privacy mode is enabled.
Disabled
(unchecked)
Battery Fail Mode Lock state set when battery fails. As-Is, Secure/Locked, Unsecure/Unlocked As-Is
Relock Delay Amount of time before the lock relocks aer being unlocked by a user presenting a
valid credential.
3
ADA Delay Amount of time before the lock relocks aer being unlocked by a user who is flagged
as handicapped and presenting a valid credential. Can be changed in the access
control system.