30 • Schlage • Schlage Utility Soware User's Guide
Lock PropertiesAD-Series Locks and Controllers
AD-400 (Networked Locks)
EDIT Tab
Property Description Default
Heartbeat The heartbeat is a brief communication from the lock to the PIM400. It allows an
idle lock to check for messages. Range: 15 seconds - many hours.
The value indicates the time between the heartbeats. Set to a shorter time (lower
number) for more frequent communication. Set to a longer time (higher number)
for less frequent communication. A smaller value will decrease battery life. A larger
value will increase battery life.
10 minutes
Comm Loss Fail Mode Lock state set when RF communication with the linked PIM400 fails.
States: As-Is, Secure/Lock, Unsecure/Unlock
As-Is
Allow Extended Unlocks
(Locks linked to
PIM400-TD2 only)
Extended unlock permits the lock to stay in an indefinite unlock state.
Enabling the Extended Unlock feature is required to implement a scheduled unlock
period from an ACP.
Enabled
Report RTX for Host to
unlock
1
Determines how an AD-400 will handle a request to exit.
If disabled, the AD-400 will only report that a request to exit has occurred. Disable
if the access point does not need to be electronically unlocked to provide egress
(if equipped with a crash bar) but the access control panel needs to be notified so
that a forced door does not occur.
If enabled, the AD-400 will report that a request to exit has occurred, and also will
query the PIM400 to determine if the AD-400 should be electronically unlocked.
Use this mode if the AD-400 needs to be electronically unlocked in order to provide
egress.
Disabled
Relatch Aer:
Timer/Door Status
Re-latch on:
Timer Only (Lock when Timer expires (default 3 seconds) regardless of Door
status or Position)
On Door Open or Timer (Lock when the Door opens or Timer expires)
On Door Close or Timer (Lock when the Door closes or Timer expires)
Timer only
High Low Output
(Locks linked to
PIM400-TD2 only)
Polarity of the Request-to-Exit (RTX) signal. Low: RTX
Polarity of the Request-to-Enter (RTE) signal. Low: RTE
Polarity of the On Door Open, (Door Position Switch (DPS)) signal. High: open
Polarity of Trouble signal. Low: trouble
First, Delay, Retry First: First query a Lock makes to a PIM400 occurs immediately following
presentation of a credential. First is the amount of time, in milliseconds, an AD-
400 should wait before making its second query to a PIM400. This setting should
be slightly greater than the fastest response time from the access control panel or
host. This optimizes battery life and system performance.
Delay: The idle time between subsequent queries. Shorter delays may reduce
latency. Longer delays may enhance battery life.
Retry: The maximum number of times an access point queries a PIM400 before
the Lock goes back to sleep. The number of retries should be slightly greater than
the longest response time from the access control panel or host. Retrys = [{Max
Response Time of Panel- First}/Delay] +1
First: 300
msec.
Delay: 200
msec.
Retry: 5
Degraded (Cache)
Mode: Card Bit Format
Enter the number of bits in the credential card number.
0 = Degraded (Cache) mode disabled
0
1. These properties are view-only when the HHD is connected to the lock. Connect the HHD to the PIM400 to make changes.